H.4 Connectivity with version 9 products
This section describes the restrictions applicable when JP1/IM - View 12-00 is connected to JP1/IM - Manager 09-00 to 09-50, when JP1/IM - Manager 12-50 is connected to JP1/IM - View 09-00 to 09-50, and when JP1/IM - Manager (Intelligent Integrated Management Base) 12-50 is connected to target JP1 products, such as JP1/Base, JP1/AJS, and JP1/PFM, whose version is 09-00 to 09-50.
- Organization of this subsection
-
(1) Restrictions placed when JP1/IM - View 12-00 is connected to JP1/IM - Manager 09-00 to 09-50 (common to all components)
JP1/IM - Manager version |
Restrictions# |
---|---|
1 to 3 |
|
09-00 |
Y |
09-01 |
Y |
09-10 |
Y |
09-50 |
Y |
No. |
Details |
---|---|
1 |
Encrypted communication cannot be established with JP1/IM - Manager. |
2 |
Connection cannot be established with JP1/IM - Manager in a different language environment. |
3 |
Operation log data cannot be output. |
(2) Restrictions placed when JP1/IM - View 12-00 is connected to JP1/IM - Manager 09-00 to 09-50 (when using the Central Console)
JP1/IM - Manager version |
Restrictions# |
|
---|---|---|
1 to 2 |
3 to 25 |
|
09-00 |
Y |
Y |
09-01 |
Y |
Y |
09-10 |
Y |
Y |
09-50 |
-- |
Y |
No. |
Details |
---|---|
1 |
Common exclusion-conditions (extended mode) cannot be defined. |
2 |
A business group or monitoring group cannot be specified for an event condition or command execution host. |
3 |
Additional common exclusion-conditions cannot be registered. |
4 |
In the Command Execution window, commands on the viewer host cannot be executed. |
5 |
In the Command Execution window, event inheritance information cannot be specified for the contents of the command to be executed. |
6 |
Repeated event conditions cannot be defined. |
7 |
Repeated events for which monitoring is suppressed by repeated event monitoring suppression cannot be displayed in consolidated format. |
8 |
Single sign-on cannot be used to connect to JP1/Navigation Platform. |
9 |
The range of automated-action suppression and the issuance of the event to notify that suppression will continue cannot be specified. |
10 |
Additional severity changing definitions cannot be registered, or severity changing definitions cannot be defined in the Severity Change Definition Settings window. |
11 |
View filters cannot be used on the Severe Events page. |
12 |
Events cannot be highlighted on the Severe Events page. |
13 |
The range of events to be collected at login cannot be set. |
14 |
Display message change settings cannot be specified. |
15 |
Program-specific extended attributes cannot be displayed in the events list in the Event Console window. |
16 |
Program-specific extended attributes cannot be specified in event conditions in the following definitions:
|
17 |
Program-specific extended attributes cannot be specified as item names in event conditions in the following definitions (program-specific extended attributes can be specified as attribute names):
|
18 |
The Suppressed event ID field and the Read Suppressed Event ID From Selected Event button are not displayed in the following windows:
|
19 |
Performance reports of event-source hosts cannot be displayed because the Display Performance menu and the Display Performance button are not displayed in the following pages and windows:
|
20 |
The event attribute values to be inherited by automated actions cannot be Base64 encoded or URL encoded. |
21 |
The JP1/AJS - Web Console monitor window cannot be displayed from the event guide by using single sign-on. |
22 |
You cannot specify the status (enabled, disabled) of automated action definitions. |
23 |
When automated action definitions are applied, you cannot inherit the suppression status and the status of satisfied conditions of the AND-joined conditions unless the action definition is edited. |
24 |
You cannot specify items for Target for exclusion in the Common Exclusion-Condition Settings (Extended) window. |
25 |
You cannot inherit arbitrary event attributes and character strings in incident manual-registration to JP1/Service Support from JP1/IM - View. |
(3) Restrictions placed when JP1/IM - View 12-00 is connected to JP1/IM - Manager 09-00 to 09-50 (when using the Central Scope)
JP1/IM - View version |
Restrictions# |
---|---|
1 to 5 |
|
09-00 |
Y |
09-01 |
Y |
09-10 |
Y |
09-50 |
Y |
No. |
Details |
---|---|
1 |
Margins of monitoring node icon and monitoring node name cannot be hidden. |
2 |
Transmission factor cannot be set for monitoring node icons. |
3 |
Status colors of monitoring node and monitoring node name cannot be changed. |
4 |
Moving of monitoring node icon cannot be suppressed in the Monitoring Tree and Visual Monitoring windows. |
5 |
Timing of the flashing alarm lamp cannot be changed. |
(4) Restrictions placed when JP1/IM - View 12-00 is connected to JP1/IM - Manager 09-00 to 09-50 (when using IM Configuration Management)
JP1/IM - Manager version |
Restrictions# |
|||
---|---|---|---|---|
1 |
2 to 4 |
5 to 7 |
8 to 17 |
|
09-00 |
Y |
Y |
Y |
Y |
09-01 |
-- |
Y |
Y |
Y |
09-10 |
-- |
-- |
Y |
Y |
09-50 |
-- |
-- |
-- |
Y |
No. |
Details |
---|---|
1 |
In the IM Configuration Management window, the following items cannot be selected from the Operation menu:
|
2 |
In the Display/Edit Profiles window, the following items cannot be selected from the menu:
|
3 |
In the Display/Edit Profiles window, Startup options is not displayed. |
4 |
In the Display/Edit Profiles window, the following items cannot be selected from the Application method radio button.
|
5 |
In the IM Configuration Management window, the following menu items are unavailable:
|
6 |
In the Register Host window, the item Remote communication type is unavailable. |
7 |
In the IM Configuration Management window, the Business Group page is not displayed. |
8 |
In the IM Configuration Management window, hosts managed by IPv6 addresses cannot be registered. |
9 |
Virtualization management information about KVM or HCSM cannot be set or displayed. |
10 |
Information about a host that holds virtualization management information about KVM or HCSM cannot be edited or deleted. In addition, Unknown is displayed as the host type. |
11 |
Event IDs and log file trap names cannot be set in the event log trap action-definitions and remote-monitoring event log trap action-definitions. |
12 |
No notification that agent settings for log file trap information might have been changed is sent while the Display/Edit Profiles window is being used. |
13 |
The enable/disable setting for starting processes automatically when the log file trap service is started cannot be changed in the Display/Edit Profiles window. |
14 |
Log file trap information for non-cluster operation cannot be applied by file transmission in the Display/Edit Profiles window. |
15 |
Host information cannot be collected unless the remote monitoring of the host whose host information is to be collected is stopped. |
16 |
In the Remote Monitoring Settings window, SSH connections cannot be set up for individual hosts. |
17 |
You cannot set more than 1,025 hosts in a single business or monitoring group. |
(5) Restrictions placed when JP1/IM - Manager 12-50 is connected to JP1/IM - View 09-00 to 09-50 (common to all components)
JP1/IM - View version |
Restrictions# |
---|---|
1 to 2 |
|
09-00 |
Y |
09-01 |
Y |
09-10 |
Y |
09-50 |
Y |
No. |
Details |
---|---|
1 |
Encrypted communication cannot be established with JP1/IM - View. |
2 |
Connection cannot be established from JP1/IM - View in a different language environment. |
(6) Restrictions placed when JP1/IM - View 09-00 to 09-50 is connected to JP1/IM - Manager 12-50 (when using the Central Console)
JP1/IM - View version |
Restrictions# |
|
---|---|---|
1 to 6 |
7 to 28 |
|
09-00 |
Y |
Y |
09-01 |
Y |
Y |
09-10 |
Y |
Y |
09-50 |
-- |
Y |
No. |
Details |
---|---|
1 |
Common exclusion-conditions (extended mode) cannot be defined. |
2 |
Command buttons are not displayed. |
3 |
Incidents cannot be manually registered in JP1/Service Support. |
4 |
The event source host attribute is not displayed (the event source host attribute can be specified for event conditions as an extended attribute). |
5 |
If restrictions are enabled on viewing and operating business groups, users cannot log in. |
6 |
Business groups and monitoring groups cannot be specified for event conditions and the command execution host. |
7 |
Additional common exclusion-conditions cannot be registered. |
8 |
The command buttons for which commands on a viewer host are specified, and for which event inheritance information is specified cannot be displayed. |
9 |
Repeated event conditions cannot be defined. |
10 |
Repeated events for which monitoring is suppressed by repeated event monitoring suppression cannot be displayed in consolidated format. |
11 |
Single sign-on cannot be used to connect to JP1/Navigation Platform. |
12 |
The range of automated-action suppression and the issuance of the event to notify that suppression will continue cannot be specified. |
13 |
Additional severity changing definitions cannot be registered, or severity changing definitions cannot be defined in the Severity Change Definition Settings window. |
14 |
View filters cannot be used on the Severe Events page. |
15 |
Events cannot be highlighted on the Severe Events page. |
16 |
The range of events to be collected at login cannot be set. |
17 |
Display message change settings cannot be specified and the messages after change cannot be displayed. |
18 |
Program-specific extended attributes cannot be displayed in the events list in the Event Console window. |
19 |
Program-specific extended attributes are specified in event conditions in the definitions listed below, but the definitions cannot be applied to JP1/IM - Manager. Also, program-specific extended attributes are specified in event conditions in the following definitions, but the event conditions cannot be displayed in windows (windows open with no event condition entered):
|
20 |
Program-specific extended attributes cannot be specified in event conditions in the following definitions:
|
21 |
Program-specific extended attributes cannot be specified as item names in event conditions in the following definitions (program-specific extended attributes can be specified as attribute names):
|
22 |
The Suppressed event ID field and the Read Suppressed Event ID From Selected Event button are not displayed in the following windows:
|
23 |
Performance reports of event-source hosts cannot be displayed because the Display Performance menu and the Display Performance button are not displayed in the following pages and windows:
|
24 |
The JP1/AJS - Web Console monitor window cannot be displayed from the event guide by using single sign-on. |
25 |
You cannot set more than 1,025 condition groups in the common exclusion-conditions in extended mode. |
26 |
The Action Parameter Definitions window cannot be displayed if you are using an action definition file where DESC_VERSION is 4. |
27 |
If automated actions are set to be excluded in the common exclusion-conditions in extended mode, the System Environment Settings window cannot be displayed. |
28 |
You cannot inherit arbitrary event attributes and character strings in incident manual-registration to JP1/Service Support from JP1/IM - View. |
(7) Restrictions placed when JP1/IM - View 09-00 to 09-50 is connected to JP1/IM - Manager 12-50 (when using the Central Scope)
JP1/IM - View version |
Restrictions# |
---|---|
1 to 5 |
|
09-00 |
Y |
09-01 |
Y |
09-10 |
Y |
09-50 |
Y |
No. |
Details |
---|---|
1 |
Margins of monitoring node icon and monitoring node name cannot be hidden. |
2 |
Transmission factor cannot be set for monitoring node icons. |
3 |
Status colors of monitoring node and monitoring node name cannot be changed. |
4 |
Moving of monitoring node icon cannot be suppressed in the Monitoring Tree and Visual Monitoring windows. |
5 |
Timing of the flashing alarm lamp cannot be changed. |
(8) Restrictions placed when JP1/IM - View 09-00 to 09-50 is connected to JP1/IM - Manager 12-50 (when using IM Configuration Management)
JP1/IM - View version |
Restrictions# |
|||
---|---|---|---|---|
1 to 2 |
3 to 5 |
6 to 9 |
10 to 18 |
|
09-00 |
Y |
Y |
Y |
Y |
09-01 |
-- |
Y |
Y |
Y |
09-10 |
-- |
-- |
Y |
Y |
09-50 |
-- |
-- |
-- |
Y |
No. |
Details |
---|---|
1 |
Virtual Manager Type is not displayed as an attribute of a host. |
2 |
For a host for which Virtual Manager Type is set as an attribute, the menu item Edit Host Properties cannot be executed. |
3 |
In the Display/Edit Profiles window, the following items cannot be selected from the menu:
|
4 |
In the Display/Edit Profiles window, Startup options is not displayed. |
5 |
In the Display/Edit Profiles window, the following items cannot be selected from the Application method radio button.
|
6 |
Information about the remote monitoring configuration is not displayed.
|
7 |
The following attributes of a host are not displayed:
|
8 |
In the Display/Edit Profiles window, Remote Monitoring is not displayed in the tree display area. |
9 |
The following Business Group menu items and page cannot be displayed or edited:
|
10 |
Virtualization management information about KVM or HCSM cannot be set or displayed. |
11 |
Information about a host that holds virtualization management information about KVM or HCSM cannot be edited or deleted. In addition, Unknown is displayed as the host type. |
12 |
No notification that agent settings for log file trap information might have been changed is sent while the Display/Edit Profiles window is being used. |
13 |
The enable/disable setting for starting processes automatically when the log file trap service is started cannot be changed in the Display/Edit Profiles window. |
14 |
Log file trap information for non-cluster operation cannot be applied by file transmission in the Display/Edit Profiles window. |
15 |
Host information cannot be collected unless the remote monitoring of the host whose host information is to be collected is stopped. |
16 |
In the Remote Monitoring Settings window, SSH connections cannot be set up for individual hosts. |
17 |
When an agent configuration is applied by using the differential distribution method, the confirmation dialog box displays as follows, not KNAN20441-Q (the agent configuration is applied by the differential distribution method).
|
18 |
You cannot set more than 1,025 hosts in a single business or monitoring group. |
(9) Restrictions placed when JP1/IM - Manager (Intelligent Integrated Management Base) 12-50 is connected to JP1 products whose version is 09-00 to 09-50
JP1 product name |
Restrictions#2 |
|
---|---|---|
1 |
2 |
|
JP1/Base |
-- |
-- |
JP1/AJS#1 |
Y |
-- |
JP1/AJS3-Web Console |
-- |
Y |
JP1/PFM |
-- |
Y |
JP1/PFM - Web Console |
-- |
Y |
No. |
Details |
---|---|
1 |
Only the functionality provided by versions earlier than JP1/AJS 09-00 to 09-50 is available. |
2 |
A connection cannot be established. |