13.7.10 Setting the event acquisition start location

The event acquisition start location is set by the -b option of the jcoimdef command. The location is determined as shown in the table below, according to the value specified in the -b option.

Table 13‒12: Relationship between -b option value and acquisition start location

Value specified in -b option

Acquisition start location

-1

The event following the last event processed by JP1/IM - Manager

0

Events registered since JP1/IM - Manager started

1 to 144

Events registered within a specified period of time before JP1/IM - Manager started

The effect of each setting is as follows:

Organization of this subsection

(1) Acquisition start location when -1 is specified

If you start JP1/IM - Manager with -1 specified in the -b option of the jcoimdef command, the event base service sends the event with the oldest serial number (the event at the location where processing stopped) to JP1/IM - Manager.

(2) Acquisition start location when 0 is specified

If you start JP1/IM - Manager with 0 specified in the -b option of the jcoimdef command, the event base service sends events registered after JP1/IM - Manager startup to JP1/IM - Manager in the order in which they were registered.

If no such events exist, the event base service remains in standby mode until a new event is registered.

(3) Acquisition start location when 1 to 144 is specified

If you start JP1/IM - Manager with any of 1 to 144 specified in the -b option of the jcoimdef command, the event base service sends events to JP1/IM - Manager that were registered within the length of time specified by the -b option before JP1/IM - Manager started.