6.9 Operation settings for automated actions

As internal processing, JP1/IM acquires events from JP1/Base, judges whether each event is a JP1 event that triggers an automated action, and executes the appropriate action if so. There is usually no need to change this internal processing, but you can halt it temporarily when a large number of redundant automated actions have been generated due to maintenance or some other activity.

To change JP1/IM settings, use the jcachange command. To check the settings, use the jcastatus command.

If you suspend internal processing, no automated actions will be executed after the system is operational again for any events that might have been received while processing was suspended. Do not suspend internal processing if there is an automated action that needs to be executed.

Note

About the jcachange command and jcastatus command:

See jcachange and jcastatus in Chapter 1. Commands in the manual JP1/Integrated Management 2 - Manager Command, Definition File and API Reference.