4.16.3 Specifying the event display start-time position by date and time

You can specify a precise start-time position by specifying the arrival time of the events you want to view. Set the desired arrival time in the event display start-time text boxes in the event display start-time specification area.

When you enter an arrival time, events saved in the integrated monitoring database are listed from the specified time up to the maximum number of viewable events (scroll buffer size). The slider in the event display start-time specification area moves to the time position that you entered in the start-time text boxes.

The defaults for the start-time text boxes depends on the time at which you were logged in to JP1/IM - Manager.

If you log in to JP1/IM - Manager later than the base time on a particular day, the base time of that day is displayed in the text boxes by default.

Example: The base time is 09:00, and you log in at 2008/07/08 10:00.

The default date and time shown in the event display start-time text boxes is 2008/07/08 09:00.

If you log in to JP1/IM - Manager earlier than the base time on a particular day, the base time of the previous day is displayed in the text boxes by default.

Example: The base time is 09:00, and you log in at 2008/07/08 08:00.

The default date and time shown in the event display start-time text boxes is 2008/07/07 09:00.