Hitachi

JP1 Version 12 JP1/Integrated Management 2 - Manager Overview and System Design Guide


4.4.4 When suppression of repeated-event display starts

This subsection describes when JP1/IM - Manager starts suppressing the display of repeated events. The descriptions in this subsection apply to all types of suppression (including the suppression of automated-action execution) imposed on the repeated events that meet a repeated event condition specified without any threshold value set.

JP1/IM - Manager determines whether to start suppressing repeated-event display when it receives an event from the event service.

JP1/IM - Manager determines whether to start suppressing repeated-event display according to each repeated event condition.

The repeated event condition set for repeated-event display excludes threshold value setting. Therefore, after JP1/IM - Manager has started, JP1/IM - Manager starts suppressing repeated-event display when it receives, from the event service, an event that meets a repeated event condition. A maximum of 2,500 types of repeated events can be targets of display suppression.

The following shows the notes on the trigger that starts suppression of repeated-event display:

In JP1/IM - Manager, there are 2,500 types of repeated events that can be the target of display suppression simultaneously for a group of events for which display suppression is activated after the threshold of the repeated event condition has been reached and another group of events that are waiting for display suppression after the repeated event condition has been met altogether.

If a new event that meets the repeated event condition occurs when the types of repeated events for which display suppression is activated and that are waiting for display suppression reach 2,500, JP1/IM - Manager operates as follows:

For the information that is displayed by JP1/IM - View when the suppression of repeated-event display starts, see 4.4.6 Event list display during the suppression of repeated-event display.