Request to swap aaaa(xx....xx) log file unable to be executed because there is no standby log file group available. (L)

A factor causing system log swapping occurred, but there was no system log file that could be swapped in.

The reasons for no available system log file are as follows.

  1. There was no standby system log file.

  2. The standby system log file group was one of the following states:

    • Was waiting for unloading

    • State in which overwriting was not possible (a sink point dump related to a particular system log file was being collected)

    • Was being read during recovery processing for the embedded database

    • Was being used for command processing

aaaa: Maintenance information

xx....xx: Maintenance information

(S)

Stops the embedded database system.

Action

Take appropriate corrective action as follows:

  • If the automatic unload function has stopped, remove the cause of the stoppage.

  • Unload the system log file.

  • Add a system log file.

  • Restore the system log file to operability.