Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVU5311-E

A system call error occurred while initializing the database of the job execution environment. (system call name : system-call-name, module : reason-location[reason-location], reason code : reason-code)

During a cold start, a system call error occurred while the database in the job execution environment was being initialized.

(S)

Interrupts the initialization of the job execution environment database, and continues the startup processing.

(O)

Determine the cause of the error from the system call name and the reason code.

The reason code is a system error number.

If the system call name is mkdir and the reason code indicates insufficient write and read permissions, set the write and read permissions for the user starting JP1/AJS3 on the work directory relevant to execution of the manager process in the job execution environment. Then, if necessary, restart.

  • The default work folder for Windows, if the installation folder is the default installation folder or is in a folder protected by the system:

    %ALLUSERSPROFILE%\Hitachi\JP1\JP1_DEFAULT\JP1AJS2\tmp

    The default for %ALLUSERSPROFILE% is system-drive\ProgramData.

    A folder protected by the system is the path to a folder in any of the following:

    - system-drive\Windows

    - system-drive\Program Files

    - system-drive\Program Files (x86)

  • The default work folder for Windows, f the installation folder is other than the above:

    JP1/AJS3 - Manager-installation-folder\tmp

  • The default work directory for UNIX:

    /var/opt/jp1ajs2/tmp

If you cannot identify the cause of the error, use the data collection tool to collect data, and then contact the system administrator.