KAVU4504-W

A pipe timeout error occurred in a job execution process at the agent(agent-host-name).

A timeout occurred during pipe communication in a job execution process.

(S)

Cancels the requested processing.

(O)

A cause may be one of the following:

  1. Too many jobs are executed at once.

  2. The CPU is heavily loaded.

  3. The agent process for job execution control was swapped out for more than 300 seconds and not executed due to insufficient real memory.

If one of these causes persists and a timeout error frequently occurs during pipe communication, we recommend that you specify a timeout period longer for pipe communication on the host where the agent process is executed.

In case of Cause No. 3, check the memory usage for the entire system and increase the memory or suppress the startup of unnecessary processes to gain sufficient real memory.

For details on how to change a timeout value for pipe communication, see 15.2.15 Changing the timeout value for pipe communication of the agent in the JP1/Automatic Job Management System 3 Configuration Guide.

If the error persists even after changing the timeout value, use the data collection tool to collect data, and then contact the system administrator.