Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVU3520-E

The monitoring thread for job (job-number) could not be generated. (reason code:reason-code)

The system failed to generate a thread for monitoring the job.

(S)

Cancels the requested processing.

(O)

The following describes the cause of the error that corresponds to each reason-code, and the corrective action to be taken.

In Windows:
  • reason-code: 8

    Memory might be insufficient. Stop unnecessary applications, and then reissue the request. If the same message reappears, re-estimate memory.

  • reason-code: 1455

    Resources might have been temporarily insufficient. Check for any processing that might have caused resources to be insufficient.

In UNIX:
  • reason-code: 12

    Memory might be insufficient. Stop unnecessary applications, and then reissue the request. If the same message reappears, re-estimate memory.

  • reason-code: 28

    The file system might not have sufficient free space. If free space is insufficient, delete unnecessary files to free more space, and then retry the operation.