KAVT7012-E

An attempt to send pipe data failed. (maintenance-information) (maintenance-information)

Interprocess communication with the agent has failed.

(S)

An error occurred during inter-process communication with the agent. The system terminates the execution interval control process depending on the location where the error occurred. If this process is terminated, the Interval Control job cannot be monitored. The Interval Control job may have failed to detect an event.

(O)

Check whether the system resources are sufficient and whether the directory created at JP1/AJS3 installation was unintentionally deleted. If the execution interval control process has started, use JP1/AJS3 - View to check the event job that caused the error, and then re-execute that job. If the execution interval control process has stopped, restart JP1/AJS3.