Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT2038-E

Monitoring can not be continued. Because the information on file of 2 Gbytes or more is contained in the status passing option file. (file-name)

Monitoring cannot be continued because the file used for storing the inherited status contains information about a file equal to or greater than 2 gigabytes.

(S)

Terminates the job abnormally.

(O)

Check whether the large file support option is set to no. If it is set to no, the large file support option may have been enabled before JP1/AJS3 stopped and the status passing option for the Monitoring Files job may have been enabled.

  • When the large file support option can be enabled:

    Enable the large file support option, restart JP1/AJS3, and then re-execute the job. Note, however, that the statuses of the files that were monitored before JP1/AJS3 stopped are not inherited.

    To enable the large file support option, specify yes for the LARGEFILEUSE environment setting parameter. For details about the environment setting parameters, see 20.11 Setting up JP1/AJS3 shared information in the JP1/Automatic Job Management System 3 Configuration Guide.

  • When the large file support option cannot be enabled:

    Make sure that the file indicated in file-name or any file under the directory specified using the wildcard characters is smaller than 2 gigabytes. Make sure that the size of the file to be monitored does not exceed 2 gigabytes during monitoring, and then re-execute the job. Note, however, that the statuses of the files that were monitored before JP1/AJS3 stopped are not inherited.

For details about the conditions for inheriting the status using the status passing option for the Monitoring Files job, see 7.6.2 Notes on the Monitoring Files job in the JP1/Automatic Job Management System 3 System Design (Work Tasks) Guide.