Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT1068-W

The specified event server is inactive. (EventServerName=event-server-name)

The JP1/Base event service specified in the EventServerName environment setting parameter has not yet started.

(S)

Because the JP1/Base event service has not started, the system continues processing while retrying the connection. A log file monitoring job cannot be monitored until the JP1/Base event service starts.

(O)

This message appears if you execute a log file monitoring job when the JP1/Base event service has not yet started or the wrong event server name is specified in the EventServerName environment setting parameter. Restart the JP1/AJS3 service after making sure that the JP1/Base event service is running and the correct event server name is set in the EventServerName environment setting parameter.