Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT0618-E

The end request for the subagent pipe could not be written. (code=maintenance-code)

An attempt to write to a pipe file used in the event/action control subagent has failed.

(S)

Terminates the event/action control subagent.

(O)

The jpoagtsub process may still remain in the system.

In UNIX, use the ps command to check whether the process remains in the system. If the process remains, use the kill command to terminate it.

In Windows, restart the system.

Check the following, and then restart JP1/AJS3:

  • Check whether system resources are sufficient.

  • Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.

  • Check whether the directory created at JP1/AJS3 installation was unintentionally deleted.