KAVT0541-E
The pipe could not be written to. (process type=process-type maintenance-information)
An attempt to write to a pipe file used in the event/action control agent has failed.
- (S)
-
Continues processing while the function of the process indicated in process-type is disabled.
- process-type
-
0: Receive JP1 Event job, Monitoring Log Files job, or Monitoring Event Log job
1: Monitoring Files job
2: Receive MQ Message job
3: Email Reception Monitoring job
4: Interval Control job
5: Receive MSMQ Message job
- (O)
-
Check the following, and then retry:
-
Check whether system resources are sufficient.
-
Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.
Check whether the directory created at JP1/AJS3 installation is unintentionally deleted. If the code indicated in maintenance-information is -1, this means that the agent process has terminated. Restart JP1/AJS3 on the agent.
-