Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT0524-W

The timer monitoring function is unusable. (maintenance-information, process name=process-name, maintenance-information)

The functions for interval control and timeout cannot be used because an attempt to start the process that executes the jobnet with these functions specified has failed.

(S)

Continues processing in a reduced mode for the function.

(O)

If you want to use this function, check the following and then restart JP1/AJS3.

If you do not intend to use these functions, ignore this message and continue operation.

  • Check whether an executable file with the same name as the process name indicated in process name=process-name exists.

  • Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.

  • Check whether memory is sufficient.

    For details on the amount of memory required by JP1/AJS3, see Memory and Disk Space Requirements in Release Notes.