KAVT0520-W

The event monitoring function is unusable. (maintenance-information, process name=process-name, maintenance-information)

The functions of the JP1 event reception monitoring job, log file monitoring job, and Windows event log monitoring job cannot be used because an attempt to start the process that executes these jobs has failed.

(S)

Continues processing in a reduced mode for the functions.

(O)

If you want to use these functions, check the following and then restart JP1/AJS3.

If you do not intend to use these functions, ignore this message and continue operation.

  • Check whether an executable file with the same name as the process name indicated in process name=process-name exists.

  • Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.

  • Check whether memory is sufficient.

    For details on the amount of memory required by JP1/AJS3, see Memory and Disk Space Requirements in Release Notes.