Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT0344-W

There is no response from the Event Action SubManager.(maintenance-information)

No response has been sent from the event/action control submanager.

(S)

Continues processing.

(O)

Check the following:

  • Check whether a mass of events has been detected.

  • For a physical host, check whether the disk that contains the JP1/AJS3 installation directory has sufficient free space. Also check whether the installation directory can be accessed.

  • For a logical host, check whether the shared disk has sufficient free space and can be accessed.

  • Check whether communication is possible with all the target hosts displayed by the ajsagtshow command.

  • Check whether any process is accessing a file in the JP1/AJS3 installation path.

  • Check whether memory is sufficient.

Correct the above problems, and then check whether the event jobs and start conditions work normally.

If they do not work normally after a while, there might be a problem with the status management of event jobs and start conditions.

Cold-start the scheduler service indicated in maintenance-information, or execute the jpomanevreset command. For details on the jpomanevreset command, see jpomanevreset in 3. Commands Used for Normal Operations in the manual JP1/Automatic Job Management System 3 Command Reference.