Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVT0062-E

An error occurred during processing of the request to end start-condition monitoring. (maintenance-information) (AjsServiceName=scheduler-service-name, UnitID=unit-ID, ExecID=execution-ID, maintenance-information)

An error occurred during the termination of monitoring the start condition.

(S)

Cancels the forced termination of the jobnet with start conditions, and continues processing.

(O)

Check the following, and then use the ajsname command with the -I option to identify the unit name from the unit ID. Make sure that the status of the identified jobnet with start conditions has not changed, and then use the ajschgstat command or the Change Job Status dialog box to change the status:

  • Check whether the system resources are sufficient. Especially, check whether there was sufficient space on the disk containing the directory for output of the wait information file during JP1/AJS3 operation.

  • Check whether the user who started JP1/AJS3 has superuser privileges or administrator privileges.

  • Check whether the directory created during installation of JP1/AJS3 was deleted inadvertently.

  • Check whether the target host and JP1/AJS3 have started.