KAVS1826-E
An IPC error occurred during file transmission, so the job (job-name) cannot be executed.: maintenance-information-1 (maintenance-information-2 maintenance-information-3)
The queueless job indicated in job-name cannot be executed due to a communication error that occurred during file transmission.
- (S)
-
Places the queueless job indicated in job-name into Failed to start status.
- (O)
-
Execute the ping or jp1ping command on both the manager host and agent host to make sure they can communicate normally, and then re-execute the queueless job indicated in job-name that resulted in the error.
In addition, correct the error according to the information indicated in maintenance-information-1, and then re-execute the queueless job indicated in job-name that resulted in the error.
If you cannot correct the problem, contact the system administrator, and collect data (see 1.2.3 To the system administrators).