Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAVS1818-E

An error occurred during internal file (file-name) processing, so the job (job-name) cannot be executed.: maintenance-information-1 (maintenance-information-2)

The queueless job indicated in job-name cannot be executed because an error occurred during processing of the internal file indicated in file-name used for execution of the queueless job.

(S)

Places the queueless job indicated in job-name into Failed to start status.

(O)

Correct the error as follows, and then re-execute the queueless job indicated in job-name that resulted in the error.

  • If No such file or directory is indicated in maintenance-information-1, make sure that the directory path specified in the internal file in file-name exists.

  • If Permission denied is indicated in maintenance-information-1, make sure that read and write permissions for the directory path to the internal file indicated in file-name are set for the user who started the queueless agent service and the OS user who executes the queueless job.

  • If any message other than the above is indicated in maintenance-information-1, correct the error according to the message. Also check the following probable causes, and then correct the error, if any.

    - The disk does not have sufficient free space.

    - Memory is insufficient.

If you cannot correct the problem by taking the above actions, contact the system administrator, and then collect data (see 1.2.3 To the system administrators).