The maximum number of waiting jobs in the class (class-name) has been reached, so the job (job-name) cannot be accepted.

The queueless job indicated in job-name cannot be accepted because both the maximum number of concurrently executable jobs and the maximum number of waiting jobs for the class indicated in class-name have been reached.

(S)

Places the queueless job indicated in job-name into Failed to start status.

(O)

Use JP1/AJS3 - View to make sure that the number of queueless jobs waiting for execution for the queueless agent service's class indicated in class-name has not reached the maximum number of waiting jobs. Make sure that the number of waiting queueless jobs is within the maximum, and re-execute the queueless job indicated in job-name that caused an error.

The current setting of the maximum number of concurrently executable jobs and the maximum number of waiting jobs for the class indicated in class-name might not suit the current operation. Review the values and then change them if necessary.

For the class, the maximum number of concurrently executable jobs is set in the AJSQL_CJOBMAX environment setting parameter, and the maximum number of waiting jobs is set in the AJSQL_CJOBWAITMAX environment setting parameter. For details, see 6.4.1 Executing jobs with a class specified in a queueless job environment in the JP1/Automatic Job Management System 3 Configuration Guide (for Windows) or 15.4.1 Executing jobs with a class specified in a queueless job environment in the JP1/Automatic Job Management System 3 Configuration Guide (for UNIX).