A new generation of the jobnet (jobnet-name) could not be created because the number of jobnet generations has reached the system limit.

The system attempted to delete one generation of execution results so that the number of jobnet generations would not exceed the limit at the following times: when a jobnet is registered for fixed execution by specifying a period or date and when an execution a schedule is added in the temporary change of the schedule. The system, however, could not create a new generation because no generations were provided with the execution results.

(S)

Cancels processing.

(O)

The combined total of the number of logs to keep and the number of scheduled generations exceeds the limit.

To register a jobnet for fixed execution by specifying a date or to add an execution schedule in the temporary change of the schedule, re-execute the operation after one or more generations being executed end.

When registering jobnets for fixed execution by specifying a period, note that generations up to the combined total of the number of logs to keep and the number of scheduled generations have been registered.

For generations that exceed 8,000, re-execute the registration after the number of generations that have been executed enables more generations to be registered.

For details about the limits for units, see B.3 Limits for units in the JP1/Automatic Job Management System 3 System Design (Configuration) Guide.