KAVS0674-E
Parameter specifications are contradictory. (unit-name parameter-name-1 parameter-name-2)
The values of parameters set in the unit configuration definition are contradictory.
The probable causes are:
-
When end judgment for a job was to be performed in a range of condition values, the range to be used as the judgment condition was not specified.
-
When monitoring is set to monitor logs of a type other than the any-log-type (when parameters other than oth are set for the unit definition parameter ntlgt) for the Windows event-log monitoring job, a log type is specified for any-log-type as the monitoring condition.
-
When a log type was specified for any-log-type for the Windows event-log monitoring job, log type was not specified as the monitoring condition.
-
When automatic retrying of jobs that end abnormally was disabled, a parameter was specified that enables retrying.
- (S)
-
Cancels command execution.
- (O)
-
Correct the unit definition parameters, and then re-execute the command.
For details about the unit definition file, see 5.1 Creating a unit definition file in the manual JP1/Automatic Job Management System 3 Command Reference.