KAVS0668-E
The value of the parameter specification range has an error.(unit-name parameter-name-1 parameter-name-2)
The value of the specifiable range of values for related parameters has an error.
The probable causes are:
-
If tho, rjs, or rje is output for parameter-name:
- The upper or lower limit of the return code for automatic retry is equal to or smaller than the abnormal end threshold.
- The lower limit of the return code for automatic retry is greater than the upper limit.
-
If ejl or ejh is output for parameter-name:
There is no integer value in the range of values for judging the return code.
-
If ejs or ejg is output for parameter-name:
There is no integer value in the range of values for judging the variable value.
- (S)
-
Cancels command execution.
- (O)
-
Correct the unit definition parameters, and then re-execute the command.
- If tho, rjs, or rje is output for parameter-name, check the following:
-
-
tho parameter (abnormal end threshold)
-
rjs parameter (lower limit of the return code for automatic retry)
-
rje parameter (upper limit of the return code for automatic retry)
-
- If ejl or ejh is output for parameter-name, check the following:
-
-
ejl parameter (minimum judgment return code)
-
ejh parameter (maximum judgment return code)
-
ejm parameter (minimum boundary condition)
-
eju parameter (maximum boundary condition)
-
- If ejs or ejg is output for parameter-name, check the following:
-
-
ejs parameter (minimum judgment value for variable (numeric))
-
ejg parameter (maximum judgment value for variable (numeric))
-
ejm parameter (minimum boundary condition)
-
eju parameter (maximum boundary condition)
-
For details about the unit definition parameters, see 5.2 Definition format and parameters in the manual JP1/Automatic Job Management System 3 Command Reference.