Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Messages


KAJS7622-E

The standard output file of the preceding job, for obtaining the set value of the global macro variable, does not exist.

The standard output file of the preceding job does not exist or is 0 bytes.

(S)

Cancels execution of the passing information setting job.

(O)

Check the following:

  • Is the preceding job a PC job, Unix job, flexible job, HTTP connection job, or custom job?

  • Is the standard output file name specified in the preceding job?

  • Did the preceding job output at least 1 byte of data to the standard output file?

Note that the information in the Execution Result Details dialog box was output by the job to standard error output. This differs from the information output to standard output.

If you recover an embedded database by using the jajs_dbrestore command, all standard output files are deleted. To re-execute the succeeding job, perform the following:

If the preceding job can be re-executed

Re-execute the preceding job.

If the preceding job cannot be re-executed
  1. Unregister the target jobnet.

  2. Set passing information and the hold attribute, and then register the jobnet for immediate execution.

  3. Prohibit execution of preceding jobs, including the passing information setting job, of the job you want to re-execute.

  4. Cancel the hold attribute of the jobnet.

  5. If the jobnet has been registered for planned execution or fixed execution, wait until the jobnet with the hold attribute canceled terminates. Then, re-register the jobnet for planned execution or fixed execution.