Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Operator's Guide


12.4.41 Define Details - [Passing Info Settings Job] - [Passing Info] dialog box

In the Define Details - [Passing Info Settings Job] - [Passing Info] dialog box, you can register or change the passing information for a job or jobnet.

The following figure shows the Define Details - [Passing Info Settings Job] - [Passing Info] dialog box.

Figure 12‒191: Define Details - [Passing Info Settings Job] - [Passing Info] dialog box

[Figure]

The following explains the displayed items.

Regular Exp.

Specify the regular expression that extracts information from the standard output file of the preceding job. You can specify a character string of a maximum of 64 bytes. The default is blank.

Output Macro Var.

Specify the macro variable name without the first five characters (?AJS2) and last character (?), as a character string of no more than 58 bytes. You can use upper-case alphabetic characters (A to Z), numeric characters (0 to 9), and periods (.).