Hitachi

JP1 Version 12 JP1/Automatic Job Management System 3 Operator's Guide


12.3.24 Register Passing Information dialog box

In the Register Passing Information dialog box, you can register or change passing information. The following figure shows the Register Passing Information dialog box.

Figure 12‒51: Register Passing Information dialog box

[Figure]

The following explains the displayed items.

Variable

Specify the macro variable name without the first five characters (?AJS2) and last character (?), as a character string of no more than 58 bytes. You can use upper-case alphabetic characters (A to Z), numeric characters (0 to 9), and periods (.).

... button

Use this button to select a macro variable name used in an existing unit in the same root jobnet. When you click this button, the Variables Used dialog box appears in which you can select a macro variable name. For details, see 12.3.25 Variables Used dialog box.

Passing Info

Specify passing information by using a character string of up to 255 bytes.

Cautionary note

In Passing Info, do not specify return or tab strokes, or any machine-dependent characters. Doing so may prevent the specified information from being passed correctly when jobnets are registered for execution.

Supplementary note

Specify a variable name so that the total number of bytes# of the macro variable name in the target unit is no more than 1,023.

Also, specify a variable name and passing information so that the total of the number of bytes# of the macro variable name and the number of bytes of the passing information in the target unit is no more than 4,085.

#

Number of bytes obtained by removing from the macro variable name ?AJS2 at the beginning and ? at the end + 4 (unit: bytes)