JP1 Version 12 JP1/Automatic Job Management System 3 Overview


5.4.10 Killing jobs

JP1/AJS3 kills an active job on receipt of a request to forcibly terminate a job or to forcibly stop the JP1/AJS3 services.

Organization of this subsection

(1) Windows execution host

Forcibly terminating an active job kills the following processes on a Windows execution agent host:

To kill these processes, the Windows OS calls the Win32API TerminateProcess function. For the function specifications, see your Windows documentation. A child process started from a user program cannot be killed.

(2) UNIX execution host

Forcibly terminating an active job kills the following processes on a UNIX execution agent host:

To kill these processes, the UNIX OS sends a SIGKILL signal to the process group. For details about process groups and SIGKILL, see the documentation relating to UNIX process control.

(3) Killing a job created by JP1/Script

Job processes created by JP1/Script (process having the extension .spt) are killed from JP1/AJS3 using SPTHTerminate, a script control interface of JP1/Script. For details about SPTHTerminate, see the manual JP1/Script Description and Reference (For Windows Systems). This interface also terminates child processes started from the JP1/Script process (.spt).

Which child processes are killed depends on whether they were started from the JP1/Script process (.spt) or from a different process, as described in the following table:

Table 5‒6: Range of killed processes

Pattern

Process call sequence

Range of terminated processes when the JP1/AJS3 process (no. 1 in the call sequence) is killed

Pattern 1

  1. JP1/AJS3 process

  2. JP1/Script process

  3. Process other than the JP1/Script process

All processes up to no. 3

Pattern 2

  1. JP1/AJS3 process

  2. JP1/Script process

  3. JP1/Script process

  4. Process other than the JP1/Script process

All processes up to no. 4

Pattern 3

  1. JP1/AJS3 process

  2. JP1/Script process

  3. Process other than the JP1/Script process

  4. Process other than the JP1/Script process

All processes up to no. 3 (no. 4 is not terminated)

If the JP1/Script process has not ended within 30 seconds of the forced termination request from JP1/AJS3, it is killed by calling the Win32API TerminateProcess function. As TerminateProcess does not kill child processes, only the JP1/Script process (no. 2 in the above patterns) is terminated.