4.9.3 Add monitored node
Function
Adds a specified node as a monitored target of JP1/Cm2/NNMi.
This plugin assumes the following server:
• NNM server (Execution target server)
This is the server on which this plugin is executed. This is a server or device that is to be added to JP1/Cm2/NNMi as a monitored target.
• Node being monitored
This is a server or device that is deleted from the targets monitored by JP1/Cm2/NNMi.
Use situation
When the number of servers to be managed has increased, you use this plugin to add a node that is to be monitored.
Prerequisites
For the latest support information about [Required product in the System]/[Required products on the execution target server]/[Prerequisite product OS running in the execution target server], see the release notes.
[Required in the System]
JP1/Automatic Operation 11-00 or later
[Required products on the execution target server]
(1) Job Management Partner 1/Cm2/Network Node Manager i 10-00, 10-10, 10-50
(2) JP1/Network Node Manager i 11-00, 11-10, 11-50, 12-00, 12-10, 12-50, 12-60
[Prerequisite product OS running in the execution target server]
(1) Windows Server 2008 R2 Standard/Enterprise/Datacenter
(2) Windows Server 2012 Standard/Datacenter, Windows Server 2012 R2 Standard/Datacenter
(3) Windows Server 2016 Standard/Datacenter
(4) Windows Server 2019 Standard/Datacenter
(5) Red Hat Enterprise Linux Server 6 (64-bit x86_64)
(6) Red Hat Enterprise Linux Server 7 (64-bit x86_64)
(7) Red Hat Enterprise Linux Server 8 (64-bit x86_64)
[Usage conditions for required products on the execution target server]
(1) When HP NNM-SE is used, the five processes ovspmd, ovwdb, pmd, ovtopmd, and netmon must be running.
Cautions
(1) An IPv6 address cannot be specified as the IP address of a monitored node.
(2) To support multi-tenancy in JP1/Cm2/NNMi, a node must be moved after it has been added.
(3) In JP1/Cm2/NNMi, it is recommended that seeds be deleted after nodes have been added (for details, see Release Notes for JP1/Cm2/NNMi).
Version
02.00.00
Plug-in tags
Configure JP1,NNMi,Windows,Linux
Plug-in name displayed in the task log
jp1nnmAddHost
Return code
0: Normal
21: Error (invalid environment) Command cannot be found (error detected in the plugin script)
27: Error (check task logs for the nature of error)
41: Error (error detected in plugin) Missing property (error detected in plugin script)
Property list
The following table lists the properties:
Property key |
Property name |
Description |
Default value |
I/O type |
Required |
---|---|---|---|---|---|
JP1CM2NNM.monitoringNodeIPaddress |
IP address of the monitored node |
Specify the IP address of the monitored node. IPv6 addresses are not supported. |
-- |
Input |
R |
JP1CM2NNM.monitoringNodeHostname |
Host name of the monitored node |
Specify the host name of the monitored node. |
-- |
Input |
O |
JP1CM2NNM.targetSubnetMask |
Subnet mask of the monitored node |
Specify the subnet mask of the monitored node. |
-- |
Input |
O |
plugin.destinationHost |
Host name of the execution target server |
Specify the host name or IP address of the server on which this plugin will be executed. IPv6 addresses are not supported. |
-- |
Input |
R |
common.returnValue |
Return value for the plugin |
The return value of this plugin stored. |
-- |
Output |
O |