2.3 Command property file (command_user.properties)
This is the definition file for setting the http port that is used for executing commands.
If you change the port number used for communications between JP1/AO and the Web browser, you must also change the http port used for executing commands to the same number.
Format
specification-key-name=setting
Installation folder
- For non-cluster systems:
JP1/AO-installation-folder\conf or /opt/jp1ao/conf
- For cluster systems:
shared-folder-name\jp1ao\conf or shared-folder-name/jp1ao/conf
Trigger for applying definitions
Updating the definition file
Description
One specification key and setting can be specified per line. Note the following points when coding the command property file.
Lines that begin with # are treated as comments.
Blank lines are ignored.
The encoding is ISO 8859-1.
The entries are case sensitive.
To specify a backslash (\) in a character string, two backslashes (\\) must be entered.
In this case, assume two backslashes as one byte to calculate the size.
If an invalid value is entered for a setting, it is set to its default value, and the KNAE02022-W message is output to the integrated trace log and public log.
If the same specification key is entered multiple times in a file, the last one that is specified will take effect.
Settings
Key name |
Settings |
Specifiable value |
Default value |
---|---|---|---|
command.http.port |
Specifies the http port used for executing commands. |
1-65535 |
22015 |
Example definitions
command.http.port = 22015