Hitachi

JP1 Version 11 JP1/Performance Management - Agent Option for Service Response Description, User's Guide and Reference


Field values

This section describes the values stored in the fields.

Organization of this page

Data source

Each field contains a value obtained from a Performance Management product or monitored program, or a value derived by applying a formula. In the tables, the Data source column indicates the source of the value or the formula used to produce the value.

For PFM - Agent for Service Response, the value of each field is the result of measurement by the IE Probe Daemon and the Probe Daemon.

Delta

In contrast to data collected as a cumulative value, the so-called delta is data that indicates the change in values. For example, if the performance data value obtained during the first collection is 3 and the performance data value obtained during the second collection is 4, then the cumulative value is 7, and the change in the values is 1. In the tables, the Delta column indicates whether or not a field's value is the delta value.

The following table explains the delta characteristics of performance data collected by PFM - Agent for Service Response:

Table 10‒6: Performance data collected by PFM - Agent for Service Response

Record type

Delta

Data type

Indicate delta value#

Record value

PI record type

Yes

--

--

--

No

Real-time data

Selected

The displayed value was the actual value at the time of data collection.

Not selected

The displayed value was the actual value at the time of data collection.

- Historical data

- Alarm monitoring data

--

The displayed value was the actual value at the time of data collection.

PD record type

Yes

--

--

--

- Historical data

- Alarm monitoring data

--

The displayed value is the cumulative value.

No

Real-time data

Selected

The displayed value was the actual value at the time of data collection.

Not selected

The displayed value was the actual value at the time of data collection.

- Historical data

- Alarm monitoring data

--

The displayed value was the actual value at the time of data collection.

PL record type

No

Real-time data

Selected

The displayed value was the actual value at the time of data collection.

Not selected

The displayed value was the actual value at the time of data collection.

- Historical data

- Alarm monitoring data

--

The displayed value was the actual value at the time of data collection.

Legend:

--: Not applicable

#

Indicates whether or not the following PFM - Web Console items are selected:

  • Indicate delta value in the report wizard's New Report > Indication settings(Realtime) window

  • Indicate delta value in Indication settings(Realtime) on the Properties page in the report window