The automatic bind settings file contains an invalid item.(line=line-number,err=description-of-the-check, value=description-of-the-setting)
An invalid item exists in the auto alarm bind setting file.
- (S)
-
Continues processing.
- (O)
-
Check the common message log. If KAVE00563-E is output, take an appropriate action according to the information provided in the message.
If the message is not output, take the following action:
Check both the auto alarm bind setting in the line in question and description-of-the-check that ended in failure, remove the problem, and then redo the previous operation. The previous operation would be one of the following:
-
Display the Automatic Bind Settings window again.
-
Set auto alarm bind again in the Automatic Bind Settings window.
-
Define the auto alarm bind setting in the auto alarm bind setting file.
One of the followings is provided as description-of-the-check:
-
Product is disabled: The product is disabled.
-
Alarm table does not exist: The specified alarm table name does not exist.
-
Business group does not exist: The specified business group name does not exist.
-
An alarm table cannot be bound to Remote Monitor: The alarm table cannot be bound to PFM - RM.
-
Data model version incompatible: The data model version is incompatible.
-
Not support alarm notifications of state changes for each instance: Instance-specific status monitoring is not supported.
-
The number of alarms to be bound exceeds the limit: The maximum number of alarm tables that can be bound per service is exceeded.
-