11.3.6 Setting operation monitoring
You must set the following items before you can duplicate definition information. Set the following information on both the primary Manager host and the secondary Manager host.
-
The following information in Table 11-2 Definition information for which the same setting must be specified on the primary Manager and the secondary Manager
-
Settings of the health check agent
-
Settings related to JP1 events
- Important
-
Match the settings between the primary Manager and the secondary Manager.
-
Set anything required for operation monitoring at the same time.
- Organization of this subsection
(1) Additional settings to be specified when you are using the auto alarm bind function
When you are using the auto alarm bind function, specify the following settings:
(a) Enabling the products
On the PFM - Manager host, execute the following command to confirm if the pre-registration of alarms or reports is enabled for the agents to which you want to apply the auto alarm bind function:
jpcconf agent list
If the pre-registration of alarms or reports is not enabled for the agents, enable it by executing the following command:
jpcconf agent setup -key service-key -register
- Note
-
If you execute the command with the service key of agents specified by mistake, you can use the following command to restore the setting back to its previous state:
jpcconf agent setup -key service-key -unregister
(b) Specifying the auto alarm bind setting
You can specify the auto alarm bind setting as follows:
- When using PFM - Web Console
-
Specify the auto alarm bind setting from the Automatic Bind Settings window. For details, see the section describing the Auto Alarm Bind Setting window in the manual JP1/Performance Management Reference.
- When using PFM - Manager
-
Directly edit the auto alarm bind setting file. For details, see the section describing the auto alarm bind setting file (jpcautobind.cfg) in the manual JP1/Performance Management Reference.
- Important
-
-
With PFM -Web Console, you only need to specify the auto alarm bind setting on the primary manager (no need to specify the same setting on the secondary manager).
-
If you change the auto alarm bind setting after configuring a multiple monitoring environment, you have to duplicate definition information again to ensure synchronization. For details, see 11.5 Duplicating definition information. For details about how to confirm synchronization, see 11.6.1(8) Checking the settings of auto alarm bind.
-