KNAS70008-E
An error occurred during service monitoring. cause=aa....aa
aa....aa: Error cause
- Description
Because an error occurred in the monitoring of a monitored service, the attempt to monitor the monitored service failed.
The meanings of the error cause are as follows:
DATA_RECEIVE: An error occurred in receiving performance data.
INTERNAL: A system failure occurred in the monitoring of a monitored service.
LOG: An error occurred in a log.
MEMORY: A memory shortage occurred.
PROPERTIES: An error occurred in a system definition file.
RMI: An error occurred in the RMI server.
STREAM: An error occurred in the receive route for performance data.
- (S)
Suspends processing.
- (O)
Take corrective action in accordance with the error cause:
DATA_RECEIVE, LOG, PROPERTIES, RMI, or STREAM:
Restart the SLM - UR service. If this does not resolve the problem, collect data, and then contact a system administrator.
INTERNAL:
Collect data, and then contact a system administrator.
MEMORY:
Stop the SLM - UR service, allocate memory, and then restart. If restarting does not resolve the problem, collect data, and then contact a system administrator.
For details about collecting data, see 7.1.6 Collecting the data needed for determining the cause of a problem.