KNAS03007-E
A communication error occurred between the SLM - UR and the SLM - Manager. destination IP address=aa....aa, destination port number=bb....bb
aa....aa: Destination IP address
bb....bb: Destination port number
- Description
A communication error has occurred for one of the following reasons:
An attempt to retry startup or termination notification from SLM - UR to SLM - Manager, in accordance with the announceRetryCount and announceRetryInterval properties in the SLM - UR jp1itslmur.properties system definition file, failed.
An attempt to retry communication between SLM - Manager and SLM - UR, in accordance with the communicationRetryCount and communicationRetryInterval properties in the SLM - Manager or SLM - UR jp1itslm.properties or jp1itslmur.properties system definition file, failed.
- (S)
Suspends processing.
- (O)
Make sure SLM - Manager or SLM - UR is running. If it is running, check and, if necessary, revise the following property values specified in a system definition file:
managerHost (jp1itslm.properties or jp1itslmur.properties)
rmiManagerPort (jp1itslm.properties or jp1itslmur.properties)
urHost (jp1itslmur.properties)
rmiUrPort (jp1itslmur.properties)