9.3.1 Configuring JP1/IM - Manager
The following describes how to configure JP1/IM - Manager.
- Organization of this subsection
(1) Enabling the response-waiting event management function
Enable the response-waiting event management function in JP1/IM - Manager. After enabling the response-waiting event management function, you can:
-
Accumulate response-waiting events
-
Cancel response-waiting events
-
Enable the settings that allow users to respond to and work with response-waiting events
The relevant settings appear in the Preferences window.
-
Filter response-waiting events
Items that allow you to select whether to filter response-waiting events appear in the Detailed Settings for Event Receiver Filter window and the Severe Event Definitions window.
To enable the response-waiting event management function:
-
Execute the jcoimdef command.
Execute jcoimdef -resevent ON.
-
Restart JP1/IM - Manager.
Note: The feature is not enabled if you use the jco_spmd_reload command.
For details about the -resevent option of the jcoimdef command, see 9.5.1 jcoimdef.
(2) Configuring the event acquisition filter
Configure the event acquisition start location so that processing continues from where it last stopped.
To set the start location of the event acquisition filter:
-
Execute the jcoimdef command.
Execute jcoimdef -b -1.
-
Execute the jco_spmd_reload command or restart JP1/IM - Manager.
For details about the jcoimdef command, see jcoimdef in Chapter 1. Commands of the JP1/Integrated Management - Manager Command and Definition File Reference.
For details about the jco_spmd_reload command, see jco_spmd_reload in Chapter 1. Commands of the JP1/Integrated Management - Manager Command and Definition File Reference.