Job Management Partner 1/IT Desktop Management 2 Automatic Installation Tool Administration Guide
Description
Initializes a RecDFile.log file to be used by the AIT_LogMessage function. Before executing the AIT_LogMessage function, be sure to execute this function.
The RecDFile.log file exists in the LOG directory path specified by either of the following registry key values.
Format
bool AIT_InitLog ( string strMessage // Message character string );
Parameters
strMessage (input)
Specify a character string message you want to write into a log file.
Return values
The return value is true if the function was executed normally, and false if not. If the function has returned false, you can use AIT_GetLastError to acquire an extended error code. The following gives the error codes that AIT_GetLastError might return:
| Extended error number | Error code |
|---|---|
| 3 | ERROR_PATH_NOT_FOUND |
| 4 | ERROR_TOO_MANY_OPEN_FILES |
| 5 | ERROR_ACCESS_DENIED |
| 8 | ERROR_NOT_ENOUGH_MEMORY |
| 14 | ERROR_OUTOFMEMORY |
| 19 | ERROR_WRITE_PROTECT |
| 32 | ERROR_SHARING_VIOLATION |
| 33 | ERROR_LOCK_VIOLATION |
| 53 | ERROR_BAD_NETPATH |
| 82 | ERROR_CANNOT_MAKE |
| 87 | ERROR_INVALID_PARAMETER |
| 112 | ERROR_DISK_FULL |
| 123 | ERROR_INVALID_NAME |
| 148 | ERROR_PATH_BUSY |
| 161 | ERROR_BAD_PATHNAME |
| 183 | ERROR_ALREADY_EXISTS |
| 206 | ERROR_FILENAME_EXCED_RANGE |
| 1005 | ERROR_UNRECOGNIZED_VOLUME |
| 1210 | ERROR_INVALID_COMPUTERNAME |
| 1214 | ERROR_INVALID_NETNAME |
| 1231 | ERROR_NETWORK_UNREACHABLE |
| 1392 | ERROR_FILE_CORRUPT |
Notes
If you have run this function, the previous RecDFile.log is changed to Rec1File.log, with a maximum of five files saved as history.
This function records the current date and time as well as messages.
All Rights Reserved. Copyright (C) 2015, Hitachi, Ltd.
Copyright, patent, trademark, and other intellectual property rights related to the "TMEng.dll" file are owned exclusively by Trend Micro Incorporated.