Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Advanced Shell Description, User's Guide, Reference, and Operator's Guide


2.8.4  Specifying environment information in JP1/IM - Manager

This subsection explains how to set up JP1/IM - Manager to use the user-reply functionality. You perform this setup in JP1/IM - Manager on the host that was specified in the HOSTNAME_JP1IM_MANAGER parameter in 2.8.1(2) Specifying the JP1 event destination host.

Organization of this subsection

(1) Copying the definition file for extended event attributes to JP1/IM - Manager

Copy the definition file for extended event attributes from the sample directory under the JP1/Advanced Shell installation directory to JP1/IM - Manager. Perform the following procedure as a user with superuser permissions.

To copy the definition file for extended event attributes and enable it:

  1. Copy the definition file for extended event attributes to the machine on which JP1/IM - Manager is installed.

    • Source definition file for extended event attributes

      The definition file for extended event attributes that is to be copied depends on the character encoding used in the target OS, as shown in the following:

      Target OS

      Definition file for extended event attributes to be copied

      Windows

      hitachi_jp1_as_SJIS_attr_ja.conf

      hitachi_jp1_as_C_attr_cn.conf

      hitachi_jp1_as_C_attr_en.conf

      AIX

      hitachi_jp1_as_SJIS_attr_ja.conf

      hitachi_jp1_as_EUC_attr_ja.conf

      hitachi_jp1_as_UTF8_attr_ja.conf

      hitachi_jp1_as_C_attr_cn.conf

      hitachi_jp1_as_C_attr_en.conf

      Linux

      hitachi_jp1_as_UTF8_attr_ja.conf

      hitachi_jp1_as_C_attr_cn.conf

      hitachi_jp1_as_C_attr_en.conf

      HP-UX

      hitachi_jp1_as_SJIS_attr_ja.conf

      hitachi_jp1_as_EUC_attr_ja.conf

      hitachi_jp1_as_UTF8_attr_ja.conf

      hitachi_jp1_as_C_attr_cn.conf

      hitachi_jp1_as_C_attr_en.conf

      Solaris

      hitachi_jp1_as_SJIS_attr_ja.conf

      hitachi_jp1_as_EUC_attr_ja.conf

      hitachi_jp1_as_UTF8_attr_ja.conf

      hitachi_jp1_as_C_attr_cn.conf

      hitachi_jp1_as_C_attr_en.conf

    • Target directory

      The following table shows the target directory to which the definition file for extended event attributes is to be copied on the machine on which JP1/IM - Manager is installed:

      Target OS

      Target directory

      Windows

      JP1/IM-Manager-console-path\conf\console\attribute\

      Or the following if JP1/IM - Manager is operating in a cluster configuration:

      shared-folder\jp1cons\conf\console\attribute\

      UNIX

      /etc/opt/jp1cons/conf/console/attribute/

      Or the following if JP1/IM - Manager is operating in a cluster configuration:

      shared-directory/jp1cons/conf/console/attribute/

      For details about JP1/IM - Manager's console path, see the Job Management Partner 1/Integrated Management - Manager Configuration Guide.

      For details about the shared folder and directory, see the description of cluster systems in the Job Management Partner 1/Integrated Management - Manager Configuration Guide.

  2. Restart JP1/IM - Manager.

(2) Setting up JP1/IM - Manager and JP1/IM - View

The function related to reply-waiting events must be enabled in JP1/IM - Manager and JP1/IM - View. If this function is not enabled, replies cannot be entered in JP1/IM - View.

For details about how to set up JP1/IM - Manager and JP1/IM - View and the settings for communication between JP1/Advanced Shell and JP1/IM - Manager, see the description related to linking with JP1/Advanced Shell in the Job Management Partner 1/Integrated Management - Manager Configuration Guide.