Job Management Partner 1 Version 10, Job Management Partner 1/Performance Management - Agent Option for Platform Description, User's Guide and Reference

[Contents][Glossary][Index][Back][Next]

Process Alive

Overview

The Process Alive alarm monitors the generation of processes that belong to a workgroup.

Use the collection data addition utility to specify monitoring of processes as follows.

Table 6-2 Settings in the collection data addition utility

Items in the collection data addition utility#1 Description#3
Match all program name, user name, and group name conditions (AND) Selected
Workgroup name workgroup
Program name#2 yyy|zzz
User name --
Group name --

Legend:
--: Not specified.

#1
Execute the collection data addition utility in an environment in which PFM - Agent for Platform has been installed. For details about how to specify the settings for collecting workgroup information, see 5.4 Settings for collecting workgroup information.

#2
For the program name, specify either of the following:
- An instance of the Process object displayed from System Monitor by choosing Administrative Tools from the Windows Start menu and then Performance and System Monitor
- Value of the Program field of the PD record.

#3
In this example, processes named yyy and zzz are set in a workgroup.

Primary settings

PFM - Web Console alarm property Settings
Item Detailed item
Main Information Product Windows
Alarm message Workgroup Application Process Count = %CVS1
Enable alarm Yes
Monitoring time range Evaluate regularly
Evaluate all data No
Report alarm when the following damping condition is reached. No
interval(s) 0
occurrence(s) during 0
Action Email --
Command --
SNMP Abnormal, Warning, Normal
Alarm Conditions 1 Record Workgroup Summary (PI_WGRP)
Field Process Count
Abnormal condition Process Count > 0
Warning condition Process Count > 0
Alarm Conditions 2 Record Workgroup Summary (PI_WGRP)
Field Workgroup
Abnormal condition Workgroup = workgroup#
Warning condition Workgroup = workgroup#

Legend:
--: Setting is always invalid.

#
Set the name of the workgroup to be monitored. This name must be set in the collection data addition utility.

Alarm table

PFM Windows Template Alarms [PS] 09.10

Related reports

Reports/Windows/Operating System/Troubleshooting/Real-Time/Drilldown Only/Process Detail