KAVU5311-E

A system call error occurred while initializing the database of the job execution environment. (system call name : system-call-name, module : reason-location[reason-location], reason code : reason-code)

During a cold start, a system call error occurred while the database in the job execution environment was being initialized.

(S)

Interrupts the initialization of the job execution environment database, and continues the startup processing.

(O)

Determine the cause of the error from the system call name and the reason code.

The reason code is a system error number.

If the system call name is mkdir and the reason code indicates insufficient write and read permissions, set the write and read permissions for the user starting JP1/AJS3 on the work directory relevant to execution of the manager process in the job execution environment. Then, if necessary, restart.

  • The default work folder for Windows Server 2012 or Windows Server 2008, if the installation folder is in the default folder or a folder protected by the system

    %ALLUSERSPROFILE%\Hitachi\JP1\JP1_DEFAULT\JP1AJS2\tmp

    The default for %ALLUSERSPROFILE% is system-drive\ProgramData.

    A folder protected by the system is the path to a folder in any of the following:

    - system-drive\Windows

    - system-drive\Program Files

    - system-drive\Program Files (x86) (for 64-bit Windows)

  • The default work folder for Windows Server 2012 or Windows Server 2008 in which an installation folder other than the above is used

    JP1/AJS3 - Manager-installation-folder\tmp

  • Default Windows Server 2003 work directory

    JP1/AJS3 - Manager-installation-folder\tmp

  • Default UNIX work directory

    /var/opt/jp1ajs2/tmp

If you cannot identify the cause of the error, use the data collection tool to collect data, and then contact the system administrator.