KAVU3112-E
Job execution control process ended abnormally. (name : process-name, code : return-code, pid : process-ID, sig : signal-number)
The process indicated in process-name terminated abnormally with the return code indicated in return-code.
When the signal number is other than 0, the process terminated abnormally in response to the signal for the signal number.
The probable causes are:
-
A JP1/AJS3 resident process was terminated abnormally by a signal.
-
A JP1/AJS3 resident process was terminated forcibly by jajs_killall.cluster command.
- (S)
-
Terminates job execution control when the process name is jpqagtdmn.
Cancels the requested processing if the process name is jpqagtchild.
- (O)
-
If you cannot determine the cause of the error, collect data and then contact the system administrator (see 1.2.3 To the system administrators in the manual Job Management Partner 1/Automatic Job Management System 3 Messages 1).
To continue the operation, collect data and then restart JP1/AJS3 (you do not have to restart JP1/AJS3 when the abnormally terminated process is jpqagtchild).
There is no problem in the following cases:
-
This message appears when you execute jajs_killall.cluster command.
-
The message KAVU3589-E has been output immediately before this message.
If this is the case and the KAVU3589-E message was output, read the message explanation and take corrective action.
-