KAVT1214-E
Making of the pipe was failed, and the search for events prior to execution cannot use. maintenance-information
An attempt to create an internal file used for the option for finding events before starting event monitoring has failed. This option cannot be used.
- (S)
-
Cancels initialization of the option for finding events before starting event monitoring. The execution status of the Receive JP1 Event job with this option specified may be invalid.
- (O)
-
Check whether the system resources are sufficient and whether the directory created during installation of JP1/AJS3 was deleted inadvertently. Change the status of the event job that is placed in an invalid status. Alternatively, if you are using a macro variable for inheriting information received by an event job, generate the event that meets the monitoring condition again.