Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Automatic Job Management System 3 Messages 1


KAVT0620-E

The subagent pipe could not be written to. (code=maintenance-code)

An attempt to write to a pipe file used in the event/action control subagent has failed.

(S)

Continues processing without changing the status of the unit (a jobnet with start conditions or an event job). If the jpoagtsub process is not running, the system terminates the event/action control subagent.

(O)

Check the following, making sure that the status of the unit (a jobnet with start conditions or an event job) has not changed, and then retry:

  • Check whether system resources are sufficient.

  • Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the Administrators group.

  • Check whether the directory created at JP1/AJS3 installation was unintentionally deleted.

  • Use a command such as a ps command to check whether the jpoagtsub process is running. If it is not running, restart JP1/AJS3.