KAVT0524-W
The timer monitoring function is unusable. (maintenance-information, process name=process-name, maintenance-information)
The functions for interval control and timeout cannot be used because an attempt to start the process that executes the jobnet with these functions specified has failed.
- (S)
-
Continues processing in a reduced mode for the function.
- (O)
-
If you want to use this function, check the following and then restart JP1/AJS3.
If you do not intend to use these functions, ignore this message and continue operation.
-
Check whether an executable file with the same name as the process name indicated in process name=process-name exists.
-
Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the Administrators group.
-
Check whether memory is sufficient.
For details on the amount of memory required by JP1/AJS3, see Memory and Disk Space Requirements in Release Notes.
-