KAVT0025-E
The last registered contents cannot be recovered because the processing to recover consistency failed.(maintenance-information)
The system cannot resume the monitoring of the jobnet with start conditions or the event job that was being monitored when the event/action control manager was stopped last time.
- (S)
-
Places the previously registered jobnet with start conditions in the Monitor terminated status or places the event job in the Unknown end status status, and then start the event/action control manager.
- (O)
-
Check the following:
-
Check whether the system resources are sufficient. Especially, check whether there was sufficient space on the disk containing the directory for output of the wait information file during JP1/AJS3 operation.
-
Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the Administrators group.
-
Check whether the directory created during installation of JP1/AJS3 was deleted inadvertently.
Because the wait information file might have been corrupted, cold-start JP1/AJS3.
-