Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Automatic Job Management System 3 Messages 1


KAVT0008-E

Failed to initialize process. (maintenance-information)

The event/action control manager could not be started.

(S)

Terminates the event/action control manager.

(O)

Check the following and then restart JP1/AJS3:

  • Check whether JP1/Base is running.

  • Check whether the system resources are sufficient.

  • Check whether the user who started JP1/AJS3 has superuser privileges or has logged on as a member of the Administrators group.

  • Check whether the contents of the environment settings are correct. In particular, check whether the name of the directory for output of the wait information file is set correctly.

    After correcting any errors, stop the JP1/AJS3 service and then restart it.