Hitachi

Job Management Partner 1 Version 10 Job Management Partner 1/Automatic Job Management System 3 Messages 1


KAJS7628-E

An error occurred during processing to read the standard output file (standard-output-file-name) of the preceding job for obtaining the set value of the global macro variable. : maintenance-information

An error occurred when reading the standard output file of the preceding job for obtaining the global macro variable value.

(S)

Cancels execution of the passing information setting job.

(O)

The probable causes are as follows:

  • When the ajsdefine command was used to define the passing information setting job, env="AJS2SO_STDOUTFILE=?AJS2SO_STDOUTFILE?"; was specified incorrectly.

  • A temporary error occurred.

If env="AJS2SO_STDOUTFILE=?AJS2SO_STDOUTFILE?"; was specified incorrectly, correct it and then execute the job again.

In the case of a temporary error, execute the job again. If the error still occurs, use the data collection tool to collect data and contact the system administrator.