KAJS7622-E

The standard output file of the preceding job, for obtaining the set value of the global macro variable, does not exist.

The standard output file of the preceding job does not exist or is 0 bytes.

(S)

Cancels execution of the passing information setting job.

(O)

Check the following:

  • Is the preceding job a PC job, Unix job, or custom job?

  • Is the standard output file name specified in the preceding job?

  • Did the preceding job output at least 1 byte of data to the standard output file?

Note that the information in the Execution Result Details dialog box was output by the job to standard error output. This differs from the information output to standard output.