Format

ajsintrpt
     [-F service-name]
     [-B execution-registration-number]
     [-R]
     [-E]
     [-T]
     [-X {yes|no|auto}]
     jobnet-name-or-job-group-name...

Description

Stops the execution of a jobnet after the currently running job is completed.

Execution privileges

You must have any of the following JP1 privileges:

Arguments

-F service-name

Specify the name of the target scheduler service.

You can specify a character string of 1 to 30 bytes.

-B execution-registration-number

Specify the execution registration number of the jobnet for which you want to stop execution, in the YYYYMMDDNNN format. The meaning of YYYYMMDDNNN is as follows:

YYYY: Year of the scheduled date of execution

MM: Month of the scheduled date of execution

DD: Day of the scheduled date of execution

NNN: Execution registration sequence number for the scheduled date of execution

For details of the execution registration number, see 4.5.13 Methods of specifying generations when executing commands in the manual Job Management Partner 1/Automatic Job Management System 3 Overview.

-R

Stops the execution of all jobnets contained in the specified job group and jobnet.

If you specify this option with the -E and/or -T options, the system stops the execution of jobnets according to the specification of each option.

-E

Stops the execution of registered jobnets.

-T

Stops the execution of the root jobnet.

-X {yes|no|auto}

Specify whether to automatically select the current unit for operation from the units listed in a planning group. The units in the job group are not, however, automatically selected regardless of the specified value. You cannot omit a root jobnet name.

  • yes

    Specify this to automatically select a target unit.

    When specifying a unit name in the command, omit a root jobnet name in a planning group.

  • no

    Specify this if you do not want to automatically select a target unit.

    You must specify a unit for which the command will operate. You cannot omit a root jobnet name in a planning group.

  • auto

    Whether a target unit will automatically be selected depends on how the unit name is specified.

    • If you want to automatically select a target unit

      Specify a unit name without a root jobnet name in a planning group.

    • If you do not want to automatically select a target unit

      Specify a unit name with a root jobnet name in a planning group. The command will operate for the specified unit only. However, if there is a unit having the same name as the path name specified without a root jobnet name in a planning group, a root jobnet name is assumed to be omitted so that a target unit will be selected automatically.

jobnet-name-or-job-group-name

Specify the name of the jobnet for which you want to stop execution. You can also specify a jobnet name or job group name with the -R, -E, or -T option.

You can specify a character string of 1 to 930 bytes.

You can specify more than one jobnet name or job group name. If you want to specify a jobnet name, however, you can specify only a root jobnet name. You cannot specify a manager job group name or manager jobnet name.

You can specify a logical host name or execution ID as a jobnet or job group name. If you specify an execution ID, however, the -B option is disabled. For details about how to specify the execution ID, see 1.1 Command syntax.

Notes

Return values

0

Normal end

Multiple of 4 within the range from 4 to 124

Abnormal end

Additional informations

Example

The following command stops the execution of jobnet net1:

ajsintrpt net1