Job Management Partner 1 Version 10, Job Management Partner 1/Automatic Job Management System 3 Operator's Guide
The following figure shows the Wait Conditions Settings List window.
Figure 15-210 Wait Conditions Settings List window
The following explains the displayed items.
Table 15-60 Information displayed in Waiting definition
Displayed Contents | Meaning |
---|---|
Not exist | The unit whose end is being waited for does not exist. Review the wait conditions, and either specify an existing unit as the unit whose end is being waited for, or delete the waiting specification for the missing unit, as the situation warrants. |
No permission | The wait conditions could not be checked because the JP1 user who opened the Wait Conditions Settings List window does not have reference permission (JP1_AJS_Guest or higher) for the unit whose end is being waited for or its upper-level unit. If the unit is one whose end can be waited for, the unit with wait conditions will start executing when the wait condition is satisfied. If the unit is not one whose end can be waited for, an error will occur when the unit with wait conditions executes. We recommend that you review the wait conditions from a user account with the appropriate permissions. For details about the units that can be specified as units whose ends are to be waited for, see 2.2.5 Using wait conditions to control the order of unit execution in the Job Management Partner 1/Automatic Job Management System 3 System Design (Work Tasks) Guide. |
Under the planning group | The wait conditions could not be checked because the unit whose end is to be waited for is created under a planning group. For details about the cautionary notes that apply when specifying a unit under a planning group as a unit whose end is to be waited for, see 2.2.5 Using wait conditions to control the order of unit execution in the Job Management Partner 1/Automatic Job Management System 3 System Design (Work Tasks) Guide. |
Unit type is invalid | The unit whose end is to be waited for is the wrong type. For details about the units you can specify as a unit whose end is being waited for, see 2.2.5 Using wait conditions to control the order of unit execution in the Job Management Partner 1/Automatic Job Management System 3 System Design (Work Tasks) Guide. |
Same unit | The same unit is specified as the unit with wait conditions and the unit whose end is being waited for. As the unit whose end is being waited for, specify a different unit from the unit with wait conditions. |
Upper unit | An upper-level unit of the unit with wait conditions is specified as the unit whose end is being waited for. As the unit whose end is being waited for, specify a unit that is not an upper-level unit of the unit with wait conditions. |
Lower unit | A lower-level unit of the unit with wait conditions is specified as the unit whose end is being waited for. As the unit whose end is being waited for, specify a unit that is not a lower-level unit of the unit with wait conditions. |
Start condition | A start condition is set for the root jobnet of the unit whose end is being waited for or the unit with start conditions. If you use a start condition, an error might occur when the unit is executed. For details, see 2.2.5 Using wait conditions to control the order of unit execution in the Job Management Partner 1/Automatic Job Management System 3 System Design (Work Tasks) Guide. |
Copyright (C) 2012, Hitachi, Ltd.
Copyright (C) 2012, Hitachi Solutions, Ltd.